Previous
Next

Counterbalance Valve Double-Acting VODL/N1116 5076 PSI

246 $
Reference VODL/N1116/12/G5.p4/ac Category Home Brand Walvoil In stock 7 Items
Product ID: 1382

Direct operated lowering brake valve - double-acting

Connection sizes: G 1/2” BSP (D1 + D2 + U1 + U2)

Nominal volume flow: 60 l/min (15,9 GPM)

Setting range: 50 bar (725,2 psi) - 350 bar (5076 psi)

Actuation ratio: 1 : 4

Max. working pressure: 350 bar (5076 psi)

Adjustment device: grub screw with lock nut

Material: Galvanized steel

  • Share this:
  • pack2_securityCreated with Sketch. Secured Payment
  • pack2_carrierCreated with Sketch. Fast Delivery
  • pack2_parcelCreated with Sketch. 24/7 Tech Support

Counterbalance Valve Double-Acting VODL/N1116 5076 PSI

246 $

Direct operated lowering brake valve - double-acting

Connection sizes: G 1/2” BSP (D1 + D2 + U1 + U2)

Nominal volume flow: 60 l/min (15,9 GPM)

Setting range: 50 bar (725,2 psi) - 350 bar (5076 psi)

Actuation ratio: 1 : 4

Max. working pressure: 350 bar (5076 psi)

Adjustment device: grub screw with lock nut

Material: Galvanized steel

Information

The purpose of lowering brake valves, also known as overcenter valves, is to prevent pulling loads on hydraulic cylinders or hydraulic motors from leading in an uncontrolled manner. The consumers are preloaded on the outlet side via the adjustable pressure valve. If necessary, this preload is released via an internal control bore, so that controlled movement is possible. The valves must always be set for the respective application. When using these valves, the center position of the upstream directional control valve to the tank must be relieved. The valve enables static and dynamic control of the load by regulating the volume flow TO and FROM the consumer through the connections U1 and U2. The valve consists of two units, each unit containing a non-return valve and a pressure relief valve. The pressure relief valves are each opened by the control pressure on the opposite side. The non-return valves allow free flow into the consumer and then block the load against unintentional reverse movements.

The pressure setting of the opposite DBV is reduced proportionally to the specified control ratio until the pressure relief valve opens and allows a controlled flow from U2 to D2 or from U1 to D1.

The spring chambers of the DBVs are relieved towards the respective connection D1 or D2. Back pressure at D1 and D2 is added to the presetting of the corresponding pressure relief valve in all functions; in order to keep this effect as low as possible, the connections of the upstream directional control valve should be relieved in the middle position to the tank.

The setting value of the DBV should be at least 1.3 times the maximum expected load pressure

Additional information:

Controlled flow from “U1” to “D1” and from “U2” to “D2”.

Schemes:

NO VIDEO PROVIDED FOR THIS PRODUCT

Volume discounts

Quantity Unit discount You Save
5 4% 49 $
10 8% 197 $
20 15% 737 $

Do you need help?

Client Contact

 

Looking for a non-standard product?

We are able to prepare a customized solution especially for you.

Looking for a non-standard product?

We are able to prepare a customized solution especially for you.