Safety Block Size 30 12VDC Normally Open SSAB
1,838 $
Product ID: 1266
Order number
General description and function:
The blocks are equipped with a main shut-off valve in P, a mechanical drain valve mechanical drain valve and a type-tested pressure relief valve.
Its use ensures that the regulations DIN 24552 Pressure Vessel Ordinance and Technical Regulations.
Pressure Vessel TRB 403/404 are fulfilled.
The built-in pressure relief valve is only used to protect the accumulator storage tank and must not be used to limit the system pressure.
Adapters for connecting the storage tanks to the storage tank safety and shut-off block must be ordered separately.
Shut-off block must be ordered separately.
×
Multi Unit Converter
PSI ⇄ Bar
PSI
Bar
Feet ⇄ Centimeters
Feet
Centimeters
Pound force ⇄ Kilograms
Lbf
Kg
Inches ⇄ Meters
Inches
Meters
GPM ⇄ Liters/min
GPM
L/min
Please select units
- Share this:
- Secured Payment
- Fast Delivery
- 24/7 Tech Support
Safety Block Size 30 12VDC Normally Open SSAB
1,838 $
Order number
General description and function:
The blocks are equipped with a main shut-off valve in P, a mechanical drain valve mechanical drain valve and a type-tested pressure relief valve.
Its use ensures that the regulations DIN 24552 Pressure Vessel Ordinance and Technical Regulations.
Pressure Vessel TRB 403/404 are fulfilled.
The built-in pressure relief valve is only used to protect the accumulator storage tank and must not be used to limit the system pressure.
Adapters for connecting the storage tanks to the storage tank safety and shut-off block must be ordered separately.
Shut-off block must be ordered separately.
Information
In addition, the blocks can be optionally equipped with an electrically operated drain valve can be fitted as an option.
The accumulator safety and shut-off block is used for systems with pressure accumulators. It is used to secure, shut off and relieve pressure accumulators.
The fixed pressure set on the pressure relief valve must be well above the system pressure.
For versions with an electric drain valve, attention must be paid to the supply voltage.
Diagrams:
![]() |
Version H (manual drain valve)
![]() |
Version EO (manual and electric drain valve)
![]() |
EC version (manual and electric drain valve)
![]() |
Explanation of symbols
1 - Sealing plug
2 - Shut-off valve
3 - Pressure relief valve
4 - Manual drain valve
5 - Electric drain valve (optional)
P - Pump connection
T - Tank connection
SP - Storage tank connection
M1/M2 - Measuring connections
Depending on the pressure set on the type-tested pressure relief valve, the following permissible pump charging currents result:
![]() |
![]() |
![]() |
*When using a pressure gauge shut-off valve with spigot and test connection in accordance with DIN 16271, seal with sealing ring (e.g. Usitring® etc.) under the hexagon on the G1/2 threaded connection, not in the threaded hole on the spigot.
![]() |
NO VIDEO PROVIDED FOR THIS PRODUCT
Volume discounts
Quantity | Unit discount | You Save |
---|---|---|
5 | 4% | 368 $ |
10 | 8% | 1,470 $ |
20 | 15% | 5,514 $ |
Do you need help?

Looking for a non-standard product?
We are able to prepare a customized solution especially for you.

Looking for a non-standard product?
We are able to prepare a customized solution especially for you.
Related Products
Last items in stock
1,838 $
Last items in stock
1,877 $
Last items in stock
1,877 $
Previous
Next