Double Analogue Slope Sensor FSAR-AN
PRICE ON REQUEST
Double analogue slope sensor
Supply voltage: 10Vdc ÷ 30Vdc
Working ambient temperature: from -40 to +70 °C
Overall dimensions (+ connector): 130 x 110 (+37) x 38 mm
Drilling interaxis: 119 x 99 mm (no. 4 M5 screws)
Protection degree: IP68
Weight: 490 g
Working range: from -60° to +60° (*)
Resolution: 0,021 mA / 0.16 degrees
Max Current absorbed with output short-circuited: 42mA (at 20mA as output)/26mA (at 4mA as output)
Max output voltage drop: Valim - 5.5V
Frequency response: 1Hz
Precision @ Tamb -20° ÷ 65°C: ± 1.07°
MTTF: 219
SFF: 99%
DC: 98%
Multi Unit Converter
PSI ⇄ Bar
Feet ⇄ Centimeters
Pound force ⇄ Kilograms
Inches ⇄ Meters
GPM ⇄ Liters/min
Please select units
- Share this:
- Secured Payment
- Fast Delivery
- 24/7 Tech Support
Information
Scheme:
![]() |
![]() |
The FSAR-AN sensor is a slope analog transducer with 4 20 mA current output. It is composed with two sensors that works separately. The output current is proportional to the inclination of the sensor compared to the horizontal position (see picture)
WORKING
Supply the sensor and read the output current (directly with a milliamperometer or connecting it to a PLC with 4÷ 20 mA current input). Attention: the input resistance of the used instrument (for the measurement) must have a value that allows to the sensor to supply the maximum current. The maximum output tension of the sensor is “Vsupply - 5.5V“.
FITTING
When you have positioned the sensor, with the long side perfectly in horizontal position, it has an output current value between 11.9mA and 12.1mA. During the fitting, it is necessary to verify that the output current, in horizontal position, is between the upon mentioned values.
CONNECTIONS
![]() |
NO VIDEO PROVIDED FOR THIS PRODUCT
Volume discounts
| Quantity | Unit discount | You Save |
|---|---|---|
| 5 | 4% | 0 $ |
| 10 | 8% | 0 $ |
| 20 | 15% | 0 $ |
Do you need help?