Previous
Next

Double Analogue Slope Sensor FSAR-AN

Price on demand
Category Home Brand Scanreco In stock 20 Items
Product ID: 1466

PRICE ON REQUEST 

Double analogue slope sensor

Supply voltage: 10Vdc ÷ 30Vdc

Working ambient temperature: from -40 to +70 °C

Overall dimensions (+ connector): 130 x 110 (+37) x 38 mm

Drilling interaxis: 119 x 99 mm (no. 4 M5 screws)

Protection degree: IP68

Weight: 490 g

Working range: from -60° to +60° (*)

Resolution: 0,021 mA / 0.16 degrees

Max Current absorbed with output short-circuited:  42mA (at 20mA as output)/26mA (at 4mA as output)

Max output voltage drop: Valim - 5.5V

Frequency response: 1Hz

Precision @ Tamb -20° ÷ 65°C: ± 1.07°

MTTF: 219

SFF: 99%

DC: 98%

  • Share this:
  • pack2_securityCreated with Sketch. Secured Payment
  • pack2_carrierCreated with Sketch. Fast Delivery
  • pack2_parcelCreated with Sketch. 24/7 Tech Support

Double Analogue Slope Sensor FSAR-AN

Price on demand

PRICE ON REQUEST 

Double analogue slope sensor

Supply voltage: 10Vdc ÷ 30Vdc

Working ambient temperature: from -40 to +70 °C

Overall dimensions (+ connector): 130 x 110 (+37) x 38 mm

Drilling interaxis: 119 x 99 mm (no. 4 M5 screws)

Protection degree: IP68

Weight: 490 g

Working range: from -60° to +60° (*)

Resolution: 0,021 mA / 0.16 degrees

Max Current absorbed with output short-circuited:  42mA (at 20mA as output)/26mA (at 4mA as output)

Max output voltage drop: Valim - 5.5V

Frequency response: 1Hz

Precision @ Tamb -20° ÷ 65°C: ± 1.07°

MTTF: 219

SFF: 99%

DC: 98%

Information

Scheme:

The FSAR-AN sensor is a slope analog transducer with 4 20 mA current output. It is composed with two sensors that works separately. The output current is proportional to the inclination of the sensor compared to the horizontal position (see picture)

WORKING

Supply the sensor and read the output current (directly with a milliamperometer or connecting it to a PLC with 4÷ 20 mA current input). Attention: the input resistance of the used instrument (for the measurement) must have a value that allows to the sensor to supply the maximum current. The maximum output tension of the sensor is “Vsupply - 5.5V“.

FITTING

When you have positioned the sensor, with the long side perfectly in horizontal position, it has an output current value between 11.9mA and 12.1mA. During the fitting, it is necessary to verify that the output current, in horizontal position, is between the upon mentioned values.

CONNECTIONS

NO VIDEO PROVIDED FOR THIS PRODUCT

Volume discounts

Quantity Unit discount You Save
5 4% 0 $
10 8% 0 $
20 15% 0 $

Do you need help?

Client Contact

 

Looking for a non-standard product?

We are able to prepare a customized solution especially for you.

Looking for a non-standard product?

We are able to prepare a customized solution especially for you.

Related Products