452 $
Single-Acting Lowering Brake Valve VBCD 5076 PSI
102 $
Product ID: 1377
Order number
Maximum pressure: 350bar (5076 psi)
Direct operated lowering brake valve - single-acting
Adjustment range: 100 (1450,4 psi) - 350 bar (5076 psi)
Adjustment device: grub screw with lock nut and cap nut
×
Multi Unit Converter
PSI ⇄ Bar
PSI
Bar
Feet ⇄ Centimeters
Feet
Centimeters
Pound force ⇄ Kilograms
Lbf
Kg
Inches ⇄ Meters
Inches
Meters
GPM ⇄ Liters/min
GPM
L/min
Please select units
- Share this:
- Secured Payment
- Fast Delivery
- 24/7 Tech Support
Single-Acting Lowering Brake Valve VBCD 5076 PSI
102 $
Order number
Maximum pressure: 350bar (5076 psi)
Direct operated lowering brake valve - single-acting
Adjustment range: 100 (1450,4 psi) - 350 bar (5076 psi)
Adjustment device: grub screw with lock nut and cap nut
Information
The purpose of lowering brake valves, also known as overcenter valves, is to prevent pulling loads on hydraulic cylinders or hydraulic motors from leading in an uncontrolled manner. The consumers are preloaded on the outlet side via the adjustable pressure valve. If necessary, this preload is released via an internal control bore, so that controlled movement is possible. The valves must always be set for the respective application. If the pressure at V2 exceeds the preload pressure of the non-return valve, the flow is released from V2 to C2. If the load pressure at C2 rises above the set value, the pressure relief valve opens and releases the flow from C2 to V2. If the load pressure at V1-C1 exceeds the set value, the pressure setting of the DBV is reduced proportionally to the specified load ratio until the pressure relief valve opens and releases the flow from C2 to V2. The DBV's spring chamber is relieved towards port V2.
Back pressure at V2 adds to the presetting of the pressure relief valve in all functions. To keep this effect as low as possible,
the connections of the upstream directional control valve should be relieved to the tank in the center position. The control line is hydraulically damped for greater stability at all volume flows and pressures.
The setting value of the DBV should be at least 1.3 times the maximum expected load pressure.
![]() |
![]() |
![]() |
Order 1 scheme:
![]() |
Order 2 scheme:
![]() |
Order 3 scheme:
![]() |
Order 4 scheme:
![]() |
Order 5 scheme:
![]() |
NO VIDEO PROVIDED FOR THIS PRODUCT
Volume discounts
Quantity | Unit discount | You Save |
---|---|---|
5 | 4% | 20 $ |
10 | 8% | 81 $ |
20 | 15% | 305 $ |
Do you need help?

Looking for a non-standard product?
We are able to prepare a customized solution especially for you.

Looking for a non-standard product?
We are able to prepare a customized solution especially for you.
Related Products
166 $
Previous
Next